Since their introduction as a commercial product in 1939, many different types of fluorescent lamp have been introduced. Systematic nomenclature identifies mass-market lamps as to overall shape, power rating, length, color, and other electrical and illuminating characteristics.
Maps, Directions, and Place Reviews
Tube designations
Lamps are typically identified by a code such as FxxTy, where F is for fluorescent, the first number (xx) indicates either the power in watts or length in inches, the T indicates that the shape of the bulb is tubular, and the last number (y) is the diameter in eighths of an inch (sometimes in millimeters, rounded-up to the nearest millimeter). Typical diameters are T12 or T38 ( 1 1/2 in or 38 mm) for residential lamps with magnetic ballasts, T8 or T26 (1 in or 25 mm) for commercial energy-saving lamps with electronic ballasts, and T5 or T16 ( 5/8 in or 16 mm) for very small lamps, which may even operate from a battery-powered device.
Reflectors
Some lamps have an internal opaque reflector. Coverage of the reflector ranges from 120° to 310° of the lamp's circumference. Often, a lamp is marked as a reflector lamp by adding the letter "R" in the model code, so a F##T## lamp with a reflector would be coded as "FR##T##". Very high output (VHO) lamps with reflectors may be coded as VHOR. No such designation exists for the amount of reflector coverage the lamp has.
Reflector lamps are used when light is only desired to be emitted in a single direction, or when an application requires the maximum amount of light. For example, these lamps can be used in tanning beds or in backlighting electronic displays. An internal reflector is more efficient than standard external reflectors. Another example is color matched aperture lights (with about 30° of opening) used in the food industry for robotic quality control inspection of cooked goods.
Aperture lamps have a clear break in the phosphor coating, typically of 30°, to concentrate light in one direction and provide higher brightness in the beam than can be achieved by uniform phosphor coatings. Aperture lamps include reflectors over the non-aperture area. Aperture lamps were commonly used in photocopiers in the 1960s and 1970s where a bank of fixed tubes was arranged to light up the image to be copied, but are rarely found nowadays. Aperture lamps can produce a concentrated beam of light suitable for edge-lit signs.
Slimline lamps
Slimline lamps operate on an instant start ballast and are recognizable by their single-pin bases.
High output/very high output lamps
High-output lamps are brighter and are driven at a higher electric current, have different ends on the pins so they cannot be used in the wrong fixture, and are labeled F##T##HO, or F##T##VHO for very high output. Since about the early to mid-1950s to today, General Electric developed and improved the Power Groove lamp with the label F##PG17. These lamps are recognizable by their large diameter (21/8"), grooved tube shape and an R17d cap on each end.
Other tube shapes
U-shaped tubes are FB##T##, with the B meaning "bent". Most commonly, these have the same designations as linear tubes. Circular bulbs are FC##T#, with the outer diameter of the circle (not circumference or watts) in centimeters being the first number and the second number referring to the tube size.
Colors
Color is usually indicated by WW for warm white, EW for enhanced (neutral) white, CW for cool white (the most common), and DW for the bluish daylight white. BL is used for ultraviolet lamps commonly used in bug zappers. BLB is used for blacklight-blue lamps employing a Wood's glass envelope to filter out most visible light, commonly used in nightclubs. Other non-standard designations apply for plant lights or grow lights.
Philips and Osram use numeric color codes for the colors. On tri-phosphor and multi-phosphor tubes, the first digit indicates the color rendering index (CRI) of the lamp. If the first digit on a lamp says 8, then the CRI of that lamp will be approximately 85. The last two digits indicate the color temperature of the lamp in kelvins (K). For example, if the last two digits on a lamp say 41, that lamp's color temperature will be 4100 K, which is a common tri-phosphor cool white fluorescent lamp.
Fluorescent Tube Socket Replacement Video
Common tube ratings
This section lists the more common tube ratings for general lighting. Many more tube ratings exist, often country-specific. The Nominal Length may not exactly match any measured dimension of the tube. For some tube sizes, the nominal length (in feet) is the required spacing between centers of the lighting fixtures to create a continuous run, so the tubes are a little shorter than the nominal length.
European energy-saving tubes
In the 1970s, Thorn Lighting introduced an energy-saving 8 ft retrofit tube in Europe. Designed to run on the existing 125 W (240 V) series ballast but with a different gas fill and operating voltage, the tube operated at only 100 W. Increased efficiency meant that the tube produced only 9% lumen reduction for a 20% power reduction. This first energy-saving tube design remains a T12 tube even today. However, follow-on retrofit replacements for all the other original T12 tubes were T8, which helped with creating the required electrical characteristics and saving on the then new (and more expensive) polyphosphor/triphosphor coatings, and these were even more efficient. Note that because these tubes were all designed as retrofit tubes to be fitted in T12 fittings running on series ballasts on 220-240 V supplies, they could not be used in 120 V mains countries with inherently different control gear designs.
Around 1980 (in the UK, at least), some new fluorescent fittings were designed to take only the newer, retrofit tubes (the lamp holders are designed not to take T12 tubes, except for 8 ft length). The earlier T12 halophosphate tubes still remained available as spares until 2012. They fit in older fittings and some modern fittings that employ twist lock lamp holders, even though the modern fittings were not electrically designed for them.
US energy-saving tubes
In the 1990s, various energy-saving tubes were introduced in the US, but unlike the T8 tubes introduced in Europe, they are not retrofits and require new matching ballasts to drive them. Running a T8 tube with a ballast for T12 will reduce lamp life and can increase energy consumption. The tube type should always match the markings on the light fixture.
T5 tubes
In the 1990s, longer T5 tubes were designed in Europe (making it to North America in the 2000s), in addition to the shorter ones (mentioned above) already in use worldwide.
T5 lamps are approximately 40% smaller than T8 lamps and almost 60% smaller than T12 lamps. T5 lamps have a G5 base (bi-pin with 5 mm spacing).
Source of the article : Wikipedia